Basic laboratory design for biosafety levels 1 and 2 containment facilities are described in the cdc nih publication biosafety in microbiological and biomedical laboratories bmbl and in the nih guidelines for research involving recombinant or synthetic nucleic acid molecules nih guidelines.
Floor plan biosafety level 2 laboratory design.
Ansi aiha z9 5 2002 laboratory ventilation august 29 2002 chapter 5 laboratory ventilation system design.
As such a separate wbdg resource page on trends in lab design has been developed to elaborate on this emerging model of laboratory design.
Specifically it describes the procedures to be used to insure a safe working environment while working with regulated recombinant dna systems infectious microorganisms or human cell cultures and human body fluids.
Workshopping with those who will be using the area themselves is essential since the lab can be tailored to what the research requires and superfluous elements can be quickly identified.
Bsl 2 labs must also provide the next level of barriers i e specialty safety equipment and facilities.
An extensive period of pre planning is vital to the design of a lab.
Single pass air is required.
The guide is formatted to address laboratory design issues pertinent to general laboratories e g chemical laboratories in section 1 with additional requirements for radioactive materials laboratories and biosafety level 2 laboratories presented in sections 2 and 3 respectively.
All persons entering the laboratory are advised of the potential hazards and meet specific entry exit requirements.
Ucsd institutional biosafety committee.
Biosafety level 2 supplement in the lab safety plan is complete.
Of biosafety level 1 2 bl1 2 contaminants handled in the laboratory address of principal investigator.
The guide is formatted to address laboratory design issues pertinent to general laboratories e g.
Equipment is decontaminated prior to repair maintenance or removal from the laboratory.
Over the past 30 years architects engineers facility managers and researchers have refined the design of typical wet and dry labs to a very high level.
Immunocompromised immunosuppressed and other persons with increased risk for infection may be denied admittance at the discretion of the laboratory director.
Uc laboratory safety design guide july 2004 chapter 3.
Access to the lab is more controlled than for bsl 1 facilities.
Negative pressure is required if adjacent area is a lower biosafety level or non laboratory space.